Used Lab Equipment
Search      
Specializing in Wholesale Purchasing, Maintenance, Service & Repair of Used Lab Equipment
 
Image1

AFAB Lab Resources LLC provides these services:

• Wholesale used lab equipment for sale
• Preventative maintenance
• Scientific instrument repair and service
• New lab installs & equipment set-up
• Liquidating your surplus laboratory equipment
• Purchasing of wholesale lab equipment
• Maintenance, service and repair of lab equipment
• Moving relocation expertise



Core Building Assets  -  HPLC

Agilent  -  Fluorescence Detector
1606-055      S/N -

Agilent  -  Automatic Fraction Collector
1606-056      S/N - DE14900258

Agilent  -  Diode Array Detector
1606-057      S/N -

Agilent  -  Isocratic Pump
1606-058      S/N -

Agilent  -  Column Compartment
1606-059      S/N -

Waters  -  AllianceBio HPLC Separations Module
1606-118      S/N - M08BA1

Waters  -  Dual Absorbance Detector
1606-119      S/N - D06487 489M

Waters  -  Photodiode Array Detector
1606-121      S/N - J03296 779M

PerSeptive Biosystems  -  Absorbance Detector
1606-122      S/N - 120/24693

Waters  -  Multi-λ Fluorescence Detector
1606-129      S/N - J03475 695M

Waters  -  Photodiode Array Detector
1606-134      S/N - MX6JM8156R

Waters  -  Separations Module
1606-137      S/N - J03SM7 038M

Waters  -  Separations Module
1606-140      S/N - A04SM9 665M

Shimadzu  -  Diode Array Detector
1606-142      S/N - L20155051163 US B

Agilent  -  Binary Pump
1606-163      S/N - DE11108596

Agilent  -  MicroALS Autosampler
1606-164      S/N - DE14900410

Agilent  -  Vacuum Degasser
1606-165      S/N - JP05032968

Agilent  -  Multi Wavelength Detector
1606-166      S/N - DE30502020

Agilent  -  Quaternary Pump
1606-167      S/N - US83104004

Agilent  -  Autosampler Thermostat
1606-168      S/N -

Agilent  -  Micro Degasser
1606-169      S/N -

Agilent  -  µWPS Wellplate Autosampler
1606-170      S/N - DE33400504

Waters  -  Autosampler
1606-200      S/N - MX6JM8517M

Shimadzu  -  Autosampler with 3725i-038 Sample Injector
1606-203      S/N - C203750

Dionex  -  HPLC Gradient Pump and Electrochemical Detector
1606-206      S/N -


 

Moving Expertise

Providing assistance to relocating-labs

More Info >>

 

 

Maintenance, Service & Repair

Let AFAB service your lab equipment

 More Info >>

 

 

New Arrivals

New products arrive every day!

Shop Now >>

 
Core Building Assets

We specialize in purchasing, moving, and the relocation of core building assets such as:
• Autoclaves
• Glass washers
• Biological Safety cabinets/Fume Hoods
• Lab casework


More Information >>

Latest News

Have you heard the exciting news?!? AFAB Lab Resources has recently undergone some structural changes – splitting into two companies – in order to better serve the needs of our diverse and growing customer base.

Share This Website



Contact AFAB Lab Resources LLC

To Reach Mike: Call (240) 375-6333
mcreath@afablabresources.com

For general questions: sales@afablabresources.com

AFAB Lab Resources LLC - Mt. Airy, MD 21771
© 2012-2016 AFAB Lab Resources LLC
Powered By KWW
 

Consign Labratory Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional Product Information:

Agilent - 1100 Series G1321A - Fluorescence Detector

The Agilent 1100 Series G1321A Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The FD's spectral information can be used for rapid method optimization and verification of separation quality.

Detection type: Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis

Performance Specifications:
• 10 fg Anthracene, Ex=250 nm, Em=400 nm*
• RAMAN (H2O) > 200 (FLF rev A)
• RAMAN (H2O) > 400 (FLF rev >A)
• Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell time constant=4 seconds (8 seconds response time)
• Light source: Xenon Flash Lamp, normal mode 20 W, economy mode 5 W
• Pulse frequency: 296 Hz for single signal mode, 74 Hz for spectral mode
• Reference System: in-line excitation measurement
• Timetable programming: up to 4 signal wavelengths, response time, PMT Gain, baseline behavior (append, free, zero), spectral parameters
• Spectrum acquisition: Excitation or Emission spectra
• Scan speed: 28 ms per datapoint (e.g. 0.6 s/spectrum 200-400 nm, 10 nm step)
• Step size: 1-20 nm
• Spectra storage: All
• Wavelength characteristic:
• Repeatability ±0.2 nm
• Accuracy ±3 nm setting
• Control and data evaluation: Agilent ChemStation for LC, Agilent 1100 Control Module with limited spectral data analysis and printing of spectra
• Analog outputs: Recorder/integrator: 100 mV or 1 V, output range >102 luminescence units, two outputs
Communications:
• Controller-area network (CAN), GPIB, RS-232C, LAN, APG
• Remote: ready, start, stop and shut-down signals
• Safety and Maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
• GLP Features: Early Maintenance Feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy, using the Raman band of water
• Housing: All materials recyclable
• Environment: 0 to 40 °C constant temperature at <95% humidity (non-condensing)
• Dimensions: 140 mm x 345 mm x 435 mm (5.5 x 13.5 x 17 in)
• Weight: 25.5 lbs


Agilent - 1100 Series G1364A - Automatic Fraction Collector

The Agilent 1100 Series G1364A Automatic Fraction Collector has three operating modes that consist of: Discrete Fractions, which is the default mode for all vessels, where the flow is diverted to waste, while moving from one vessel position to the next vessel position; Continuous Low is available only when using the deep well plates; and Needle Into Location where the needle pushes into the vessel as deep as specified, for the use with capped vials and test tubes and well plates with closing mats.

Specifications:
• Max. tube/plate height: 48 mm
• Max. tube volume: ca. 20 ml or unlimited, if funnels are used with external containers
• Max. flow rate: 10 ml/min (depending on viscosity and generated back pressure, max 6 bar at the diverter valve)
• Safety features: Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors.


Agilent - 1100 Series G1315B - Diode Array Detector

The Agilent 1100 G1315B Diode Array Detector verifies separation quality with peak purity, multiple signals, and spectral libraries during analytical quantification, offering an extended wavelength range with the highest sensitivity. The diode array detector allows for automated wavelength verification for performance tracking. The Agilent 1100’s temperature management system ensures optimum baseline stability, even under rough ambient conditions. This detector features superb illumination using combined deuterium and tungsten lamps for the highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution. The programmable slit helps you explore the spectral landscape for faster sample characterization, ensuring higher sensitivity or lower baseline noise as necessary on the 1100. Slit settings can be stored and reported from 1 – 16 nm with raw data for GLP traceability.

Specifications:
• Detection type: 1024-element photodiode array
• Light Source: Deuterium and tungsten lamps
• Wavelength range: 190 – 950 nm
• Short term noise (ASTM) single and multi-Wavelength: ± 1 × 10-5 AU at 254 and 750 nm
• Drift: 2 × 10-3 AU/hr at 254 nm
• Linear absorbance range: > 2 AU (upper limit)
• Wavelength Accuracy: ± 1 nm
• Wavelength bunching: 1 – 400 nm
• Slit width: 1, 2, 4, 8, 16 nm
• Diode Width: < 1 nm
• Flow Cells: Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
• Control and data evaluation: Agilent ChemStation for LC
• Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
• Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
• Safety and maintainence: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas
• GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.
• Housing: All materials recyclable


Agilent - 1100 Series G1310A - Isocratic Pump

Specifications:
• Hydraulic System: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
• Setable Flow Range: 0.001 — 10 ml/min, in 0.001 ml/min increments
• Flow Range: 0.2 — 10.0 ml/min
• Flow Precision: <0.07% RSD, or <0.02 min SD whatever is greater, based on retention time at constant room temperature
• Flow Accuracy: ±1% or 10µl/min whatever is greater
• Pressure: Operating range 0 — 40 MPa (0 — 400 bar, 0 — 5880 psi) up to 5 ml/min Operating range 0 — 20 MPa (0 — 200 bar, 0 — 2950 psi) up to 10 ml/min
• Pressure Pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar (147 psi)
• Compressibility Compensation: User-selectable, based on mobile phase compressibility • Recommended PH Range: 1.0 — 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
• Control and Data Evaluation: Agilent ChemStation for LC
• Analog Output: For pressure monitoring, 2 mV/bar, one output
• Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional


Agilent - 1100 Series G1316A - Column Compartment

The HP Agilent 1100 G1316A Colcom thermostatted column compartment is built with two heat exchangers for solvent pre-heating, automated column identification module and CAN cable. The compartment’s compact size conveniently fits into a single Agilent 1100 Series HPLC stack. The G1316A offers a temperature range of 10° below ambient to 80° C and temperature stability of ± 0.15°C. The HP Agilent G1316A has a column capacity of three 30 centimeter columns and can utilize a temperature accuracy of ± 0.8°C. The warm up/cool down of the G1316A is 5 mins from ambient to 40°C. Peltier heating and cooling allows for high heating and cooling speeds for maximum flexibility and stability.

Specifications:
• Temperature Range: 10° below ambient to 80° C
• Temperature Stability: ± 0.15°C
• Temperature Accuracy: ± 0.8°C
• Column Capacity: Three 30cm columns
• Warm-up/Cool Down: 5 mins from ambient to 40°C
• Dead Volume: 3 ul left heat exchanger, 6 ul right heat exchanger
• Dimensions (H x W x D): 5.5 x 16 x 17 in (14 x 41 x 43.5 cm)


Waters - e2796 - AllianceBio HPLC Separations Module

The Waters e2796 Bioseparations Module is designed for robust and reliable operation under harsh salt and pH conditions typical of bioseparations, it features an insert flow path, making it ideal for protein purification, peptide mapping, and nucleic acid analysis.

Samples can be processed standard 96 (shallow and deep) well plates, 384-well microtiter plates, and custom plates, 2 mL vials, or 0.5 and 1.5 mL microcentrifuge tubes.

Specifications:
• Electrical Requirements: 100-240 V, 9.5 A, 47-63 Hz
• Dimensions: 24 x 17 x 22.5
• Weight: 116 lbs


Waters - 2487 - Dual Absorbance Detector

The Waters 2487 detector features advanced programmability, dual wavelength capability, unmatched signal-to-noise performance, reduced optical bandwidth and exceptional linearity to provide the highest performance in UV/VIS detection for your HPLC analyses. The innovative TaperSlit flow cell design and Lamp Optimization Software deliver the sensitivity to detect minor impurities coupled with the linear dynamic range to simultaneously quantitate major and minor components.

Specifications:
• Wavelength Range: 190 to 700 nm
• Bandwidth: 5 nm
• Wavelength Accuracy: ± 1 nm
• Wavelength Repeatability: ± .10 nm
• Noise, single wavelength: < ± 0.35 x 10-5 AU, dry cell, 254 nm, 1.0 sec. time constant (TC)
• Noise, dual wavelength: < ± 2.5 x 10-5 AU, dry cell, 254 nm / 280 nm, 2.0 sec. time constant (TC)
• Linearity: 5% at 2.5 AU, dry cell, 254 nm / 280 nm, 2.0 sec. time constant (TC)
• Drift: 1.0 x 10^4 AU/Hour/degrees Celcius at 254 nm (after 1 hour warmup)
• Sensitivity setting range: 0.0001 to 4.0000 AUFS
• Dimensions: 19.5 x 10.75 x 8 in
• Weight: 20 lbs


Waters - 2996 - Photodiode Array Detector

The Waters 2996 Photodiode Array Detector delivers exceptional chromatographic and spectral sensitivity alongside reliability. Analytical and preparative separations are simple with this advanced spectral analysis tool, featuring enhanced homogeneity assessment and component recognition. It offers unprecedented detection and quantification of trace impurities. The unit features start-up diagnostics to ensure superior performance prior to use. Maximum chromatographic sensitivity means unprecedented trace impurity detection and quantification, while optimized spectral sensitivity and purity algorithms allow definitive compound identification and coelution detection.

Specifications:
• Wavelength Range: 190 to 800 nm
• Wavelength Accuracy: ±1 nm
• Maximum Pressure: 1000 psi, 68.9 bar
• Linearity Range: 5% at 2.0 AU, propylparaben, at 256 nm
• Spectral Resolution: 1.2 nm
• Baseline Noise: ±1.5 x 10^-5 AU peak-to-peak, dry, at 254 nm
• Drift: 1 x 10^-3 AU/hour at 254 nm (after warmup), ∆T ≤ 1 C per hour
• Dimensions: 24 x 11.5 x 8.5 in
• Electrical Requirements: Low trigger < 1.8 V, High trigger > 3.0 V, Protected to ±30 V, Minimum pulse width 20 msec, Maximum current 5 mA
• Weight: 27 lbs


PerSeptive Biosystems - UVIS-205 - Absorbance Detector

Specifications:
• Wavelength range 190-800 nm, 1 nm increment
• Wavelength accuracy ±1nm, bandwidth 6nm
• Wavelength precision: ±0.1nm
• Absorbance range: 0.0005 to 3.0 AUFS
• Electrical Requirements: T2.5A SB Fuse - 100 V, 120 V. T1.25A SB Fuse - 220 V, 240 V. 225 VA, 50/60 Hz
• Dimensions: 19.5 x 12 x 9 in
• Weight: 35.5 lbs


Waters - 2475 - Multi-λ Fluorescence Detector

The Waters 2475 Fluorescence Detector offers unsurpassed sensitivity for quantifying low concentrations of target compounds, whether naturally fluorescent or derivatized with a fluorescent tag. The 2475 detector sets the standard for fluorescence method development with 3D and “on-the-fly” spectral scanning for determining the optimal emission and excitation wavelengths, with the ability to monitor up to four independent wavelength pairs.

Specifications:
• Wavelength Range: Ex: 200 to 890 nm, Em: 210 to 900 nm
• Bandwidth: 20 nm (maximum)
• Wavelength Accuracy: ±3 nm
• Wavelength Repeatability: ±0.25 nm
• Sensitivity, Single Channel: 1 to 100,000 EUFS
• Filter Setting Range, Single Channel: 0.1 to 5.0 seconds, Hamming (default), 0.1 to 99 seconds, RC
• Filter Setting Range, Multichannel: 1 to 50 seconds, Hamming (default), 1 to 99 seconds, RC
• Lamp Source: Xenon arc lamp (150 W)
• Flow Cell: Axial Illuminated Flow Cell design
• Cell Volume (Illuminated): 8 µL (standard analytical)
• Pressure Limit: 145 psi (flow rate not to exceed 5 mL/min)
• Operating Temperature: 4 to 40 C (39.2 to 104 F)
• Operating Humidity: 20 to 80% noncondensing
• Dimensions: 19.5 x 11 x 8 in
• Weight: 28 lbs


Waters - 996 - Photodiode Array Detector

The Waters 996 Photodiode Array Detector can be used for both detection and identification of compounds, making it sensitive and versatile. Its optics bench contains a 10 mm, 8 uL Taperbeam flow cell which reduces baseline noise while maximizing the response with a long pathlength and a small cell volume. The use of elliptical mirrors increases light transmission giving noise performance of ±1.5 x 10-5 AU with a slit that is optimized for 1.2 nm optical resolution. It operates exclusively with Waters Empower software to provide complete spectral acquisition and results management. The photodiode array detector is the only "No Compromise" PAD available today with excellent sensitivity, linearity, optical and chromatographic resolution.

Specifications:
• Wavelength Range: 190 to 800 nm
• Wavelength Accuracy: ±1 nm
• Linearity Range: 5% over -0.1 to 2.0 AU
• Spectral Resolution: 1.2 nm per photodiode
• Baseline Noise: 5 x 10 -5 AU peak-to-peak
• Drift: 1 x 10 -3 AU/hour at 254 nm (after warmup)
• Operating Temperature: 4 to 40°C (39° to 104°F)
• Operating Humidity: 20 to 80% non-condensing
• Flow Cells: Standard Pathlength: 10 mm, Semi-Preparative Pathlength: 3 mm, Microbore Pathlength: 6 mm, Inert Pathlength: 10 mm
• Electrical Requirements: 100-240 V, 50/60 Hz, 3.5 A, F4a/250V
• Maximum Pressure: 1000 psi, 68.9 bar
• Dimensions: 23 x 11 x 8 in
• Weight: 29 lbs


Waters - 2695 - Separations Module

The Waters 2695 Separations Module can be used for in-vitro diagnostic testing to analyze many compounds, including diagnostic indicators and therapeutically monitored compounds. The Separations Module is an integrated solvent and sample management platform. This integration of two traditional high performance liquid chromatography (HPLC) components—a solvent management system and a sample management system—streamlines all critical separations functions.

Specifications:
• Operating Temperature: 4 to 40 C (39 to 104 F)
• Relative Humidity: 20 to 80%, noncondensing
• Acoustic Noise: <65 dB(A)
• Power Requirements: 950 VA (maximum), 85 to 132 Vac or 180 to 250 Vac, 47 to 63 Hz
• Effective System Delay Volume: <650 µL
• Plunger Seal Wash: Integral, active, programmable
• Dry Prime/Wet Prime: Automatic, front panel control
• Flow Ramping Time: (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate
• Maximum Operating Pressure: 5000 psi (345 bar)
• Pressure Ripple: ≤2.5%
• Composition Range: 0.0 – 100.0 in 0.1% increments
• Composition Accuracy: ±0.5% absolute
• Composition Precision: ≤0.15% RSD or ≤0.02 min SD
• Flow Precision: ≤0.075% RSD or ≤0.02 min SD
• Flow Accuracy: ±1% or 10 µL/min


Waters - 2795 - Separations Module

Waters offers the Alliance High Throughput (HT) HPLC System to help laboratories meet the demand of 24/7 operation. Built around the 2795 Separations Module, Alliance HT Systems optimize automated sample and solvent management to shave valuable seconds from each step of the chromatography process. The system is designed specifically to improve the productivity of labs that require the selectivity and sensitivity of LC/MS to produce quality data.

Specifications:
• Number of solvents: one to four
• Gradient profiles: 11 gradient curves
• Solvent conditioning: vacuum degas
• Maximum operating pressure: 5000 psi
• Compressibility compensation: automatic and continuous
• Sample plates: total of four plates
• Power requirements: 950 VA (Maximum)


Shimadzu - SPD-M20A - Diode Array Detector

The SPD-M20A High Performance Liquid Chromatography PDA detector provides users with the most advanced level of sensitivity and stability found in today's PDA detectors. Sharing many of the qualities of the SPD-20A/20AV UV-Vis Detectors, the SPD-M20A attains sensitivity levels approaching the most advanced UV-Vis detectors. It has a high-sensitivity mode with an 8 nm slit width. Using light-source compensation, it offers a noise level of 0.6×10-5 AU, which is comparable to that of traditional UV-VIS detectors.

Specifications:
• Light source: Deuterium (D2) Lamp
• Number of diode elements: n/a
• Wavelength range: 190 to 700 nm
• Bandwith, slit width: 8 nm
• Wavelength accuracy: 1 nm maximum
• Functions: Dual-wavelength detection in range 190 to 370 nm and upwards 371, ratio-chromatogram output, wavelength scanning
• Power requirements: 100 VAC, 160 VA, 50/60 Hz


Agilent - 1100 Series G1312A - Binary Pump

The Agilent 1100 G1312A Binary Pump ensures virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. The G1312A’s inlet-valve is electronically activated and synchronized to piston stroke to eliminate vapor formation with volatile solvents and requires no maintenance. The high-speed proportioning valve and preconfigured vacuum degasser of the 1100 Binary Pump allows convenient low-pressure mixing of up to four solvents and the highest flexibility in solvent choices. This binary pump can be remotely controlled via chemstation software or by an external G1323 controller. The Agilent G1312A is easy to use, durable, and offers a wide flow range.

Specifications:
• Setable Flow Range: Setpoints 0.001 to 5 ml/min, in 0.001 ml/min increments
• Flow Range: 0.1 to 5 ml/min
• Flow Precision: ≤ 0.07% RSD or ≤ 0.02 min SD
• Flow Accuracy: ± 1% or 10 ul/min
• Pressure: Operating range 0 to 400 bar (0 to 5880 psi) up to 5 ml/min
• Pressure Pulsation: < 2% amplitude (typically < 1%) at 1 ml/min isopropanol, at all pressures > 1 MPa
• Compressibility Compensation: User-selectable, based on mobile phase compressibility
• Hydraulic System: Two dual pistons in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve
• Recommended pH Range: 1.0 to 12.5; solvents with pH < 2.3 should not contain acides with attack stainless steel
• Gradient Formation: High-pressure binary mixing, delay volume 180 to 480 ul without mixer, 600 to 900 ul with mixer, dependent upon back pressure
• Composition Range: 1 to 99% or 5 ul/min per channel
• Composition Precision: ≤ 0.5% absolute
• Composition Accuracy: ≤ 0.15% RSD at 1 ml/min


Agilent - 1100 Series G1389A - MicroALS Autosampler

The Agilent 1100 Series Thermostatted Micro Autosampler has a settable injection volume allowing for 0.01 to 8 µl with a small loop capillary and 0.01 to 40 µl with an extended loop capillary. There is a precision of < 0.5 % RSD from 5 to 40 µl, < 1 % RSD from 1 to 5 µl, and < 3 % RSD from 0.2 to 1 µl. The G1389A features a Thermostattable Tray for 100 x 2 ml vials and can be used with microvials (100 or 300 µl) with sleeves. It has early maintenance feedback (EMF) and electronic records of maintenance and errors. Safety features include a leak detection and safe leak handling, low voltages in maintenance areas, and error detection and display.

Specifications:
• Sample capacity: 100 x 2 ml vials in 1 tray. Microvials (100 or 300 ul) with sleeves (reduced cooling performance with microvials)
• Settable injection volume: 0.01 to 8 ul with small loop capillary
• 100 position sample tray
• Line Voltage: 100 – 120 or 220 – 240 VAC, ± 10 %
• Line frequency: 50 or 60 Hz, ± 5 %
• Power consumption (apparent power): 300 VA maximum
• Power consumption (active power): 200 VA maximum power
• Ambient operating temperature: 4 – 55 C (41 – 131 F)
• Ambient non-operating temperature: 40 to 70 C (-4 to 158 F)
• Humidity: < 95 %, at 25 – 40 C (77 – 104 F) non-condensing


Agilent - 1100 Series G1322A - Vacuum Degasser

The Agilent 1100 G1322A Degasser provides fast and easy flushing, purging, priming, and solvent exchange by low internal volume (1 ml per channel). This degasser, with less internal flow restrictions than other models, is a perfect fit for applications and solvents with higher flow rates. Its robust design allows high instrument uptime, with solvents passing through a gas-permeable membrane tube with a constant vacuum level. The vacuum pump generates a partial vacuum in the vacuum container, allowing dissolved gases to permeate through the membranes for degassing.

Specifications:
• Max Flow Rate: 10 ml/min per channel, reduced performance above 5 ml/min
• Number of Channels: 4
• Internal Volume: 1 ml/channel
• Materials in Contact with Solvent: PTE, PEEK
• pH Range: 1 – 14
• Analog Output (AUX): For pressure monitoring, range 0 – 3 V
• Electrical Requirements: 100-120 or 220-240 VAC, 50/60 Hz


Agilent - 1100 Series G1365B - Multi Wavelength Detector

The Agilent 1100 G1365B Multi-Wavelength Detector offers excellent sensitivity for both single and multiple wavelength detection. It utilizes deuterium and tungsten lamps with a wavelength range of 190 to 950 nm, offering an expanded detection range with lowest detection limit. The diode array design enables simultaneous acquisition of up to eight compound-specific wavelengths for increased sensitivity and selectivity. The programmable slit (1 to 16 nm) also allows rapid optimization of sensitivity, linearity, and spectral resolution.

Specifications:
• Detection Type: 1024-element photodiode array
• Light Source: Deuterium and tungsten lamps
• Wavelength Range: 190 – 950 nm
• Short Term Noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
• Drift: 2 × 10-3AU/hr at 254 nm
• Linear Absorbance Range: > 2 AU (upper limit)
• Wavelength Accuracy: ± 1 nm
• Wavelength Bunching: 1 – 400 nm
• Slit Width: 1, 2, 4, 8, 16 nm
• Diode Width: < 1 nm
• Power Requirements: 100-120/220-240 V, 300 VA, 50/60 Hz


Agilent - 1100 Series G1311A - Quaternary Pump

The HP Agilent 1100 Series G1311A Quat Pump ensures virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices. It is one of the most rugged and durable liquid chromatograph systems on the market today. It is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions. Instrument comes equipped with four solvent inlets with built-in gradient control. The gradient formation is performed by a low pressure gradient valve.

Specifications:
• Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve
• Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments
• Flow range: 0.2 – 10.0 ml/min
• Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
• Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min, Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min
• Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa (10bar)
• Electrical Requirements: 100-120 or 22-240 VAC, 50/60 Hz, 220 VA


Agilent - 1100 Series G1330B - Autosampler Thermostat

The Agilent G1330B Thermostat provides consistent heating and cooling for tight temperature control during HPLC assays. It is built to be partnered with a fraction collector or autosampler and can hold either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials. It heats and cools through use of Peltier controlled heat exchangers, that draws air from above the sample area and blows it through the fins of the module, then the Thermostated air enters the autosampler to be distributed evenly for effective control. During cooling, condensation will appear however the water will be guided out of the thermostat. It has a settable range from 4 to 40 C, set in 1 degree C with an accuracy of 3 to 9 C.

Specifications:
• Temperature Range: 4 to 40 C
• Ambient Temperature: 4 to 40 C
• Power Requirements: 100-120/220-240 V, 50/60 Hz


Agilent - 1100 Series G1379A - Micro Degasser

The Agilent 1100 G1379A Degasser features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. It generates a partial vacuum in the vacuum container, allowing dissolved gases to permeate through the membranes for degassing. It has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance.

Specifications:
• Maximum Flow Rate: 0 to 5 ml/minute per channel, 5 to 10 ml/minute at reduced degassing performance
• Ambient Operating Temperature: 0 to 55 C
• Ambient Non-Operating Temperature: -40 to 70 C
• Power Requirements: 100-120/220-240 VAC, 50/60 Hz, 30 W


Agilent - 1100 Series G1377A - µWPS Wellplate Autosampler

The Agilent 1100 Series G1377A uWPS Micro Wellplate Autosampler is designed to perform capillary LC with injection of sample volumes ranging from nL to uL. Features a micro Rheodyne valve and the optimized design of the needle seat, loop and seat capillaries minimize dispersion. A high-resolution metering device offers resolution ten times better than a standard autosampler, bypass operation facilitates low delay volume, increased sample injection speed for high sample throughput, flexible and convenient sample handling with different types of sample containers. Using 384-well plates allows to process up to 768 samples unattended.

Specifications:
• GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
• Communications: Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
• Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
• Injection range: – 8 µl in 0.01 µl increments with the small loop capillary, – 40 µl in 0.01 µl increments with the extended loop capillary
• Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl,Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl
• Injection cycle time: Typically, < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl
• Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm, Mobile phase: Water/Acetonitrile = 85/15, Column Flow rate: 13 µl/min, Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover, Outside wash of needle before injection: 20 sec with water using flush port
• Power Requirements: 100-120/220-240 V, 300 VA, 50/60 Hz


Waters - 717 Plus - Autosampler

The Waters 717 Plus HPLC Autosampler combines the automation, ease of use, reliability, and low cost-of-ownership needed for the high productivity laboratory. It incorporates a highly reliable and extremely precise fluid path design that is versatile enough to use for all your methods and applications.

Specifications:
• Injection Volume Range of 1.0 microliter to 2000 microliter in 0.1 microliter increments
• Bandspreading of <10% contribution for all solvent systems
• System Operating Pressure of 4500 psig (31027 Kpa)
• Wash Flow, Solvent Rate of >0.4 mL per injection
• Power Requirements: 100/120/220/240 V, 600 VA, 50/60 Hz, 4/5 A


Shimadzu - FRC-10A - Autosampler with 3725i-038 Sample Injector

The Shimadzu FRC-10A Fraction Collector collects both analytical and preparative fractions. -standard configuration has a 144 5mL vial capacity -for automated collection of thermally-labile fractions, Peltier temperature control keeps temperatures stable within a 4-70C range -choose from collection criteria such as volume, threshold, and peak purity -a precise peak division feature ensures high purity fractions -automatically adjusts for retention time shifts, so that only the peak of interest is collected -slope-override capability enables continued collection, even when the detector signal is off-scale.


Dionex - GP-50 & ED40-1 - HPLC Gradient Pump and Electrochemical Detector

Specifications for the Gradient Pump:
• Pumphead Volume: 100 uL
• Moduleware Rev: 3.51
• Dual-piston, variable speed, 100 µL stroke
• Operating pressure 5000 psi maximum
• Flow rate up to 10.0 mL/min, in 0.01 mL/min step

Specifications for the Electrochemical Detector:
• Detector range: 0.01 µS to 3000 µS, full scale (Conductivity), 50 pC to 200 µC (Integrated Amperometry), 50 pA to 300 µA (DC Amperometry)
• Temperature compensation: 0.0 to 3.0% per ºC (Conductivity)
• Cell drive: Variable 8 kHz square wave (Conductivity), ±2.04 V (DC and Integrated Amperometry)
• Cell body: PEEK
• Active volume: 1.0 µL
• Maximum pressure: 2.0 mPa (300 psi)
• Electrodes: 316 stainless steel
• Amperometry cell active volume: ∼ 0.2 µL
• Amperometry cell maximum pressure: 0.7 mPa
• Amperometry cell reference electrode: Combination pH–Ag/AgCl