Used Lab Equipment
Search      
Specializing in Wholesale Purchasing, Maintenance, Service & Repair of Used Lab Equipment
 
Image1

AFAB Lab Resources LLC provides these services:

• Wholesale used lab equipment for sale
• Preventative maintenance
• Scientific instrument repair and service
• New lab installs & equipment set-up
• Liquidating your surplus laboratory equipment
• Purchasing of wholesale lab equipment
• Maintenance, service and repair of lab equipment
• Moving relocation expertise



Core Building Assets  -  Spectrophotometers

Shimadzu  -  Recording Spectrophotometer
1606-038      S/N - A10833780567

Shimadzu  -  UV-Visible Spectrophotometer
1606-062      S/N - A10753782013

Thermo Finnigan  -  Mass Spectrometer System
1606-074      S/N - LXP00368

Eppendorf  -  UV/Vis Photometer
1606-090      S/N - 613200389

Waters  -  Mass Spectrometer
1606-115      S/N - HAA 023

Beckman  -  Spectrophotometer System
1606-158      S/N - 4318535

Agilent  -  8453 UV-visible Spectrophotometer
1606-176      S/N -


 

Moving Expertise

Providing assistance to relocating-labs

More Info >>

 

 

Maintenance, Service & Repair

Let AFAB service your lab equipment

 More Info >>

 

 

New Arrivals

New products arrive every day!

Shop Now >>

 
Core Building Assets

We specialize in purchasing, moving, and the relocation of core building assets such as:
• Autoclaves
• Glass washers
• Biological Safety cabinets/Fume Hoods
• Lab casework


More Information >>

Latest News

Have you heard the exciting news?!? AFAB Lab Resources has recently undergone some structural changes – splitting into two companies – in order to better serve the needs of our diverse and growing customer base.

Share This Website



Contact AFAB Lab Resources LLC

To Reach Mike: Call (240) 375-6333
mcreath@afablabresources.com

For general questions: sales@afablabresources.com

AFAB Lab Resources LLC - Mt. Airy, MD 21771
© 2012-2016 AFAB Lab Resources LLC
Powered By KWW
 

Consign Labratory Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional Product Information:

Shimadzu - UV-2401PC - Recording Spectrophotometer

This system a low stray light/wide dynamic range/small beam size combination makes this instrument well suited to handle a variety of practical situations. From small sample volumes to highly absorbing samples, the software gives the power and versatility of an extremely sophisticated system in a package that's easy to learn and use.

Specifications:
• Wavelength range: 190 to 900 nm
• Single monochromator with a high-performance blazed holographic grating in the aberration corrected Czerny-Turner mounting
• Resolution: 0.1 nm
• Spectral bandwidth: 0.1, 0.2, 0.5, 1, 2 and 5 nm
• Wavelength repeatability: ±0.1 nm
• Wavelength accuracy: ±0.3 nm
• Wavelength scanning speed: Fast, medium, slow and super slow
• Light source: 50 W halogen lamp and D2 lamp
• Light source lamp switching: Select between 282 nm and 393 nm
• Stray light: Less than 0.015% at 220nm and 340nm
• Photometric system: Double-beam, direct ratio system with dynode feedback
• Photometric mode: Absorbance (Abs.), transmittance (%), reflectance (%) and energy (E)
• Photometric range: Absorbance -4~5 Abs. (0.001 Abs. increments)
• Transmittance: 0~999.9% (0.01% increments)
• Reflectance: 0~999.9% (0.01% increments)
• Photometric accuracy ±0.002 Abs. (0~0.5 Abs.) with NIST 930D Filter. ±0.004 Abs. (0.5~1 Abs.) with NIST 930D Filter. ±0.3%T (0~100%T) with NIST 930D Filter
• Photometric repeatability: ±0.001 Abs. (0~1.0 Abs.) ±0.1%T
• Baseline flatness: Within ±0.001 Abs. (excluding noise; 2nm slit width and SLOW wavelength scanning speed)
• Drift: Less than 0.0004 Abs. per hour (after 2 hours warm-up)
• Power Requirements: 100V, 120V, 220V, 240V, switch-selectable; 50/60Hz
• Software Specifications: Personal Spectroscopy Software (standard), Spectrum, Quantitative, Time Course
• Dimensions: 25 x 22 x 11 in
• Weight: 75 lbs


Shimadzu - UV-1601 - UV-Visible Spectrophotometer

The Shimadzu UV-1601 PC is a UV/Visible double beam spectrophotometer. It provides high performance with an optical bench that's equipped with a monochromator for trouble-free operation.

Comes with a power cord. Software not included.
Specifications:
• Lighting: 50W halogen lamp, on-board automatic light source positioning mechanism.
• Photometric System: double beam optics
• Wavelength Range: 190-1100 nm
• Operating Conditions: Room temperature 15-35 C, Humidity 45-80%
• Bandwidth: 2 nm
• Scanning Speed: 3200 nm/min to 160 nm/min
• Detector: Silicon photodiode
• Optical System: Monochromator uses aberration-correcting concave blazed holographic grating
• Photometric Range: Absorbance of -0.5~3.999 Abs / Transmittance of 0.0~300%
• Distance between beams: 100 mm
• Additional Specifications Wavelength Accuracy: +/- 0.5 nm
• Wavelength Reproducibility: +/- 0.1 nm
• Wavelength Display: readable to 0.1 nm
• Wavelength Setting: 0.1 nm increments
• Wavelength Slew Rate: about 6000 nm/min
• Photometric Accuracy: +/- 0.004 Abs at 1.0 Abs
• Dimensions: 21.5 x 18 x 8 in
• Weight: 37.5 lbs


Thermo Finnigan - LCQ Deca XP - Mass Spectrometer System

The LCQ Deca XP is a quadrupole ion trap mass spectrometer made with high sensitivity, ruggedness, and continuous data generation. This system couples an orthogonal API source and Ion Sweep technology resulting in increased signal to noise ratios and reduced API solvent ion noise. This system features a split-flow turbomolecular pump, an integrated divert valve and syringe pump.

Specs:
• Mass range: m/z 150 to 2000 daltons
• Scan power: MSn, for n = 1 to 10
• MS/MS Sensitivity: 50:1
• Resolution: Normal unit mass scan, 10000 HR
• Scan speed: 28 ~ 66000 amu / sec
• Dimensions: 28" x 31" x 31"


Eppendorf - BioPhotometer Plus - UV/Vis Photometer

With the BioPhotometer Plus, Eppendorf offers a compact UV/Vis photometer for use in molecular biology, biochemistry and cell biology. The photometer provides instant, out-of-the-box access to 32 routine methods, of which 9 methods are freely programmable.

Specifications:
• Optical system: Absorption singlebeam photometer with reference beam
• Light source: Xenon flash lamp
• Light beam height: 8.5 mm
• Measuring wavelengths: 230, 260, 280, 340, 405, 490, 550, 595, 650 nm
• Spectral bandwidth: 5 nm at 230–340 nm, 7 nm at 405–650 nm
• Wavelength systematic error: ±1 nm at 230–280 nm, ±2 nm at 340–650 nm
• Photometric measuring range: 0 to 3 A (2 A at 340 nm); Dye Methods: 2 A at 550 nm/650 nm
• Photometric random error: ±0.002 A at 0 A; ±0.005 A at 1 A
• Photometric systematic error: ±1 % at 1 A
• Calibration memory: For all calibration procedures
• Results memory: For 100 results with absorbance and ratio values, sample number, sample dilution, date and time
• Power requirement: Approx. 20 W in operation, approx. 10 W in Standby mode
• Power supply: 100–240 V, 50/60 Hz, <0.3 A, 20 W
• Dimensions: 13 x 8 x 3.5 in
• Weight: 7.6 lbs
• Cuvettes: UVette, Hellma TrayCell, and common rectangular cuvettes of suitable glass or plastic materials


Waters - Q-Tof Premier - Mass Spectrometer

The Q-Tof Premier Mass Spectrometer, featuring T-Wave (Travelling Wave) technology, offers significant enhancements in mass measurement accuracy, dynamic range (pDRE), sensitivity (Enhanced Duty Cycle) and speed. Waters Q-Tof Premier offers the finest blend of innovative analytical capabilities for results to quantify, identify and characterize compounds from simple or complex mixtures.

Specifications:
• High sensitivity: High transmission efficiency of ZSpray source technology, T-Wave ion optics, T-Wave collision cell and oa-Tof transmission result in high sensitivity
• High resolution: Up to 17,500 FWHM with W-Optics
• High mass measurement capability: Routine exact mass measurement (3 ppm RMS) in MS and MS/MS with LockSpray and NanoLockSpray
• Enhanced speed: Faster TDC (4 GHZ) delivers acquisition speeds of up to 20 spectra per second—compatible with UPLC-based separations
• Dynamic Range Enhancement (pDRE): Equipped with programmable DRE function, which enables quantitation and exact mass measurement over 4 orders of magnitude
• Enhanced Duty Cycle: Enables enhanced sensitivity over targeted m/z ranges for detection of modified components MALDI — Exchangeable vacuum MALDI source enabling large scale MALDI MS and MS/MS analyses: compatible with 96- and 384-spot target plates
• Resolving quadrupole: 4, 8 and 32k Da options
• m/z range: up to 100,000 in V-Optics
• Intelligent, automated MS/MS acquisition: Data Directed Analysis (DDA) and Precursor Ion Discovery
• Source options: LockSpray, NanoLockSpray, IonSABRE, APCI, ESCi and APPI
• Optional: ACQUITY UPLC System
• Power: 2 kW, 10 Amps Maximum, 50/60 Hz, 220 to 240 Volts
• Dimensions: 42 x 28 x 52 in
• Weight: 765 lbs


Beckman - DU640 - Spectrophotometer System

A microprocessor controlled spectrophotometer intended for use in quantitative and qualitative biological research and industrial procedures, the Beckman Coulter DU 640 Spectrophotometer is ideal for operations requiring spectrophotomic measurements in the UV-visible region of the electromagnetic spectrum. This unit operates in the wavelength range of 190 to 1100 nm.

***NOTE*** Includes Dell Ultrasharp Monitor (1504FP) and Logitech Mouse (811209)

Specifications:
• Power: 50/60Hz, 100/120/220/240V, 1.8A @ 100-120V, 09.A @ 220-240V
• Dimensions: 21 x 28 x 27 in
• Weight: 88 lbs


Agilent - G1103A - 8453 UV-visible Spectrophotometer

The Agilent 8453 UV-Visible spectrophotometer uses a photodiode array for fast acquisition, exceptional reliability, and virtually absolute wavelength repeatability. Simultaneous measurement across the ultra-violet to visible light spectrum eliminates scanning. Powerful data analysis and archival software ensure compliance with good laboratory practices (GLP) and pharmacopoeia requirements.

Device comes with its own power supply.

Specifications:
• Type: UV-Visible
• Wavelength Range: 190 to 1100 nm
• Resolution: 1 nm
• Optical System: Single Beam
• Detector(s): Photodiode Array
• Light Source: Deuterium and Tungsten Lamps
• Scanning Speed: Acquisition in less than 1 sec.
• Wavelength Accuracy: Less than +/- 0.5 nm