Agilent 1100 Series HPLC System

$14,500.00

1 in stock



SKU: 009458 Category:

Description

Agilent 1100 Series HPLC System

This item comes with a 30-day Repair or Replace warranty.   

This HPLC system is in very good condition. All operational testing was completed successfully, and each unit functions as intended. We used in-house software for testing. Please Note: If you need computer and software, please contact us for information prior to ordering, otherwise will come only with what is shown.

G1313A – Autosampler  

  • Injection Range: 0.1 µL to 100 µL, with 0.1 µL increments  
  • Replicate Injections: 1 to 99 per vial  
  • Sample Capacity: 100 x 2 mL vials per tray  
  • Minimum Sample Volume: 1 µL from a 5 µL sample in a 100 µL micro vial  
  • Injection Cycle Time: Typically, 50 seconds  
  • Carryover: Typically, < 0.01% to < 0.05%  
  • Sample Viscosity Range: 0.2 cp to 50 cp  
  • Physical Dimensions: 200 mm (height) x 345 mm (width) x 435 mm (depth)  
  • Weight: 14.2 kg (31.3 lbs)  
  • Power Requirements: 100-120 or 220-240 VAC, ± 10%, 50 or 60 Hz 

G1316A – Thermostatted Column Compartment (TCC)

  • Temperature Range: 10°C below ambient to 80°C  
  • Temperature Stability: ± 0.15°C  
  • Temperature Accuracy: ± 0.8°C  
  • Column Capacity: Three 30 cm columns  
  • Warm-up/Cool Down Time: 5 minutes from ambient to 40°C    

G1315B – Diode Array Detector (DAD) 

  • Detection Type: 1024-element photodiode array  
  • Light Source: Deuterium and tungsten lamps  
  • Wavelength Range: 190 – 950 nm  
  • Short Term Noise: ± 1 x 10^-5 AU at 254 and 750 nm  
  • Drift: 2 x 10^-3 AU/hr at 254 nm  
  • Linear Absorbance Range: > 2 AU (upper limit)  
  • Wavelength Accuracy: ± 1 nm  
  • Slit Width: Programmable slit widths of 1, 2, 4, 8, and 16 nm  
  • Flow Cells: Various options including standard, semi-micro, micro, high pressure, and nano flow cells  
  • Control and Data Evaluation: Agilent ChemStation for LC  
  • Analog Outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs  
  • Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote, LAN optional  
  • Safety and Maintenance: Extensive diagnostics, error detection, leak detection, and safe leak handling  
  • Power Requirements: 100 – 240 VAC, 50 or 60 Hz, 300 VA / 125 W / 427 BTU 

G1312A – Binary Pump  

  • Weight: 34 lbs.  
  • Dimensions: 7 x 13.5 x 17 in. 
  • Electrical: 100 – 240 VAC, ± 10% ~ 50/60Hz ~ 220VA ~ 74W ~ 253BTU  
  • Ambient Operating Temp: 4–55 °C (41–131 °F)  
  • Ambient Non-Operating Temp: -40–70 °C (-4–158 °F)  
  • Maximum Operating Pressure: 600 bar (8700 psi)  
  • Flow Rate Range: 0.1 – 5 mL/min  
  • Flow Precision: < 0.07% RSD or < 0.02 min SD  
  • Flow Accuracy: ± 1% or 10 µL/min 

G1379A – Micro Vacuum Degasser  

  • Channels: 4-channel vacuum container  
  • Membranes: 4 micro-structured membranes  
  • Vacuum Pump: Integrated  
  • Internal Volume: 480 µL per channel  
  • Maximum Flow Rate: 10 mL/min per channel  
  • Operating Temperature: 4–55 °C (41–131 °F)  
  • Power Consumption: 30 VA 