pH/C-900 Monitor:   

  • Accuracy: The greater of ± 2% of full scale or ± 10 µS/cm in the range 1 µS/cm-300 mS/cm ± 0.1 pH unit, temperature compensated Max. 0.1 pH units within 0–10 ml/min (pH measurement)   
  • Operating pressure max.: 50 bar (5 MPa) (725 psi)   
  • Conductivity: 1 µS/cm-999.9 mS/cm   
  • Operating Temperature: 4°C-40°C   
  • Relative humidity: 20%-95% (non condensing)   
  • Baseline noise: ± 0.5% of full-scale calibrated range   
  • Drift: Max. 0.02 pH/h (measured at pH 4.0) ±0.5 °C per 10 h 0.1 pH unit deviation/10 h   
  • Cell Constant: 50 ± 20 cm-1   
  • Response Time: Max. 10 s (0–95% of step) (pH measurements) Max. 3 s (0–95% of step) (Conductivity measurement)   
  • Voltage: 100-120/220-240 VAC   
  • Protection class: IP 20 (Housing) IP 44 (Flow cell)   
  • Material: Glass Perfluororubber (FFKM) Polyetheretherketone (PEEK) Polytetrafluoroethylene (PTFE) Titanium alloy (Ti alloy) Chlorotrifluoroethylene (CTFE)     

UV-900 Monitor:  

  • Accuracy: ±2 nm   
  • Operating pressure max.: 2 MPa   
  • Operating Temperature: 4°C-40°C   
  • Relative humidity: 20%-95% (non condensing)   
  • Linearity: < 2% deviation up to 2 AU at 260 nm with Uracil at pH 2   
  • Baseline noise: < 60 μAU at 230 nm   
  • Drift: < 2×10-4 AU/h at 254 nm   
  • Voltage: 100-120/220-240 VAC   
  • Protection class: IP 20   
  • Material: Polyetheretherketone (PEEK) Polytetrafluoroethylene (PTFE) Titanium alloy (Ti alloy) Glass      

P-900 Pump:  

  • Accuracy: ±2% or 20 μl/min whichever is greater (0.2–10.0 MPa)   
  • Analog Output: Pressure, 0 to 1V   
  • Chemical stability: The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100% Ethylacetate, 100% Hexane, and 100 % Tetrahydrofuran (THF).   
  • Connections: Fingertight connector   
  • Flow rate: 0.01-100 ml/min  
  • Material: Polyetheretherketone (PEEK) Polytetrafluoroethylene (PTFE) Ethylenechlorotrifluoro-ethylene (ECTFE) Polyvinylidenefluoride(PVDF) Polyethylene (PE) Titanium Titanium alloy (Ti alloy) Aluminium oxide (Al oxide) Ruby Zirconia Super high resistent stainless steel   
  • Operating pressure max.: 100 bar (10 MPa) (1450 psi)   
  • Operating Temperature: 4°C- 40°C   
  • Power consumption: Max. 400 VA with all extra components connected   
  • Protection class: IP 20 (Housing)   
  • Relative humidity: 20%-95% (non condensing)   
  • Viscosity Max.: 5 cP  
  • Voltage: 100-120/220-240 VAC 