Description
Agilent 1100 Series HPLC System
This item comes with a 30-day Repair or Replace warranty.  Â
This HPLC system is in very good condition. All operational testing was completed successfully, and each unit functions as intended. We used in-house software for testing. Please Note: If you need computer and software, please contact us for information prior to ordering, otherwise will come only with what is shown.
G1329A – AutosamplerÂ
- Injection Range: 0.1 to 100 µLÂ
- Injection Precision: < 0.5% RSDÂ
- Sample Capacity: 100 × 2 mL vials or 2 × 96 well platesÂ
- Carryover: < 0.05%Â
- Injection Cycle Time: 15 secondsÂ
- Temperature Control: Optional, 4-40°CÂ
- Dimensions (DxWxH) : 13.6 x 17.1 x 7.1 inÂ
- Weight:Â 24 lbs.Â
G1330B – Autosampler ThermostatÂ
- Operating Temperature Range: 4 to 40°C (39 to 104°F)Â
- Operating Humidity Range: < 95%, non-condensingÂ
- Maximum Power Consumption: 260 VA (210 W)Â
- BTU: 717
G1316A – TCCÂ
- Temperature Range: 10°C below ambient to 80°CÂ
- Temperature Stability: ± 0.15°CÂ
- Temperature Accuracy: ± 0.8°CÂ
- Column Capacity: Three 30 cm columnsÂ
- Warm-up/Cool Down Time: 5 minutes from ambient to 40°CÂ
G1315B – DADÂ
- Detection Type: 1024-element photodiode arrayÂ
- Light Source: Deuterium and tungsten lampsÂ
- Wavelength Range: 190 – 950 nmÂ
- Short Term Noise: ± 1 x 10^-5 AU at 254 and 750 nmÂ
- Drift: 2 x 10^-3 AU/hr at 254 nmÂ
- Linear Absorbance Range: > 2 AU (upper limit)Â
- Wavelength Accuracy: ± 1 nmÂ
- Slit Width: Programmable slit widths of 1, 2, 4, 8, and 16 nmÂ
- Flow Cells: Various options including standard, semi-micro, micro, high pressure, and nano flow cellsÂ
- Control and Data Evaluation: Agilent ChemStation for LCÂ
- Analog Outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputsÂ
- Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote, LAN optionalÂ
- Safety and Maintenance: Extensive diagnostics, error detection, leak detection, and safe leak handlingÂ
- Power Requirements: 100 – 240 VAC, 50 or 60 Hz, 300 VA / 125 W / 427 BTU
G1311A – Quaternary PumpÂ
- Power: 100 – 240 VAC, ± 10% ~ 50/60Hz ~ 180VA ~ 55W ~ 188BTUÂ
- Ambient Operating Temp: 4–55 °C (41–131 °F)Â
- Ambient Non-Operating Temp: -40–70 °C (-4–158 °F)Â
- Humidity: < 95%, at 25–40 °C (77–104 °F), non-condensingÂ
- Operating Altitude:Â Up to 2000 m (6500 ft)Â
- Hydraulic System:Â Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers, and active inlet valveÂ
- Settable Flow Range: 0.001 – 10 ml/min, in 0.001 ml/min incrementsÂ
- Flow Precision: ≤ 0.07% RSD, or ≤ 0.02 min SD, whichever is greater, based on retention time at constant room temperatureÂ
- Flow Accuracy: ± 1% or 10 μl/min, whichever is greaterÂ
- Pressure Operating Range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min; 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/minÂ
- Pressure Pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 1 MPa (10 bar)Â
- Compressibility Compensation:Â User-selectable, based on mobile phase compressibilityÂ
- Recommended pH Range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steelÂ
- Gradient Formation:Â Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valveÂ
- Delay Volume: 800 – 1100 μl, dependent on back pressureÂ
- Composition Range: 0 – 95 % or 5 – 100 %, user selectableÂ
- Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/minÂ
- Communications:Â Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optionalÂ
G1322A – Vacuum DegasserÂ
- Channels: 4-channel vacuum containerÂ
- Components: Includes 4 tubular plastic membranes and a vacuum pumpÂ
- Function: The vacuum pump generates a partial vacuum in the vacuum container, which is measured by a pressure sensor Â