Endress + Hauser Raman Rxn2 Spectrometer Analyzer

$79,500.00

1 in stock



Description

Endress + Hauser Raman Rxn2 Spectrometer Analyzer

This analyzer system is in very good condition. From working lab, in full working condition. This is a base model 785 nm, 4 channel configuration. All components with this unit are listed below. This system was purchased new, in 2022. If you have specific questions, please ask prior to ordering.

Raman Rxn2   

  • Model No.: KRXN2B-1056/0 
  • Raman Rxn2 analyzer with embedded technology · 
  • Optical composition analysis based on Raman spectroscopy   
  • CalCheck and AutoCal technologies   
  • IP20 enclosure  
  • ETL and CE electrical marked  
  • Robust fiber optic connectivity  
  • External independent interlock connectivity  
  • Application laboratory to process development 160,076.76 160,076.76  
  • Approvals non-hazardous area B  
  • Wavelength: 785 nm  
  • Channel Configuration 4  
  • Spectral Coverage and Resolution 100-3425 cm-1, 4 cm-1 
  • Ambient Operating Temperature: 15 to 30 °C (59 to 86 °F)
    Storage Temperature: -15 to 50 °C (5 to 122 °F) 
  • Relative Humidity: 20 to 80 %, non-condensing 
  • Input Voltage: 100-240 V, 50-60 Hz, ±10% 
  • Power consumption: 400W (max).

Raman Rxn-10 KR10   

  • Model No.: KR10-10A1/0 
  • Quantity: 4 ea. 
  • Raman Rxn-10 probe ·  
  • Raman probe head to be used with either non-contact or immersion optics ·  
  • Integrated mechanical shutter ·  
  • Applications: For use in general purpose areas in laboratory, process development, or manufacturing Wavelength 785 nm  
  • Connector Electro-optic male   
  • Length 10 m (393.71 inch)

Raman Bio Optic KLBIO1  

  • Model No.: KLBIO1-1020/0 (KLBIO1-ABAA) Raman bioprocessing optic · 
  • Quantity: 2 ea.  
  • In situ measurement optic for bioprocessing ·  
  • Temp (min/max): -30 to 150 °C (-22 to 302 °F) ·  
  • Pressure (max): less than 200 psi (less than 13.78 Barg) ·  
  • Cleanability: Autoclavable; CIP/ SIP under standard industry conditions ·  
  • Easy-to-use, fixed focus, sealed design ·  
  • Optimized for use with Rxn-10 probe head ·  
  • Applications: For use in laboratory and process development   
  • Wavelength: 785/1000 nm  
  • Immersion Length: 220 mm (8.67 inch)  
  • Material: SS316L  
  • Process Connection: PG13.5

Model no.: KLBIO1-1040/0 (KLBIO1-ADAA)  

  • Raman bioprocessing optic ·  
  • Quantity: 2 ea. 
  • In situ measurement optic for bioprocessing ·  
  • Temp (min/max): -30 to 150 °C (-22 to 302 °F) ·  
  • Pressure (max): less than 200 psi (less than 13.78 Barg) ·  
  • Cleanability: autoclavable; CIP/ SIP under standard industry conditions ·  
  • Easy-to-use, fixed focus, sealed design ·  
  • Optimized for use with Rxn-10 probe head ·  
  • Applications: For use in laboratory and process development  
  • Wavelength 785/1000 nm  
  • Immersion Length 420 mm (16.54 inch)  
  • Material SS316L  
  • Process Connection PG13.

Model no.: KHCA1-1020/0 (KHCA1-B1) 

  • Quantity: 1  
  • Raman calibration accessory · Certificate of calibration · Compatible with fiber, probe, and optics adapters  
  • Wavelength 785 nm

Model no.: 70187785  

  • HCA adapter for 12 mm (0.472 inch) immersion optics and Rxn-45 probes 
  • Quantity: 1

Model no.: 70187796 

  • Quantity: 1    
  • KLBIO1/Rxn-45 verification chamber SC 
  •  Sample chamber for 12 mm (0.472 inch) probes

Model no.: 70199421 

    • Quantity: 1 ea. 
    • Pred, RT v6.4+, 4Ch, Simca QPp, v17.0    
    • Simca v17 predictor compatibility for Raman Runtime v6.4+ for a 4-channel analyzer.  
    • Note: excludes Python scripting capability 

Ebay

Contact Us

Additional information

Weight 120 lbs
Dimensions 30 × 38 × 65 in

260 Interstate Circle
Suite 2A
Frederick , MD 21704

Call us

301 803 9722
240 375 6333