G4220A – Binary Pump
- Ambient Operating Temp: 4–55 °C (39–131 °F)
- Humidity < 95 % r.h. at 40 °C (104 °F) Non-condensing
- Operating Altitude: Up to 2000 m (6562 ft)
- Flow Precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—2.0 ml/min).
- Pressure Operating Range: Operating pressure range 120 MPa (1200 bar), up to 2 ml/min.
- Line Voltage: 100 – 240 V~, ± 10 % Wide-ranging capability
- Line Frequency: 50 or 60 Hz, ± 5 %
- Power Consumption: 350 VA / 270 W / 922 BTU Maximum
- Weight: 48 lbs.
- Dimensions (DxWxH) 17 x 13.5 x 9.3 in.
G4226A – Autosampler
- Ambient Operating Temperature: 4–55 °C (39–131 °F)
- Humidity < 95 % r.h. at 40 °C (104 °F) Non-condensing
- Operating altitude Up to 2000 m (6562 ft)
- Sample Capacity: Flexible, including two well plates and 10 x 2 mL vials, or 30 x 6 mL vials
- Sample Viscosity Range 0.2 – 5 cp
- Line Voltage 100 – 240 V~, ± 10 % Wide-ranging capability
- Line Frequency 50 or 60 Hz, ± 5 %
- Power Consumption 200 VA / 200 W / 683 BTU Maximum
- Weight: 34.2 lbs.
- Dimensions (DxWxH): 17 x 13.5 x 8 in.
G1330B – Thermostat
- Ambient Operating Temperature: 4 – 40 °C (39 – 104 °F)
- Humidity: < 95 % r.h. at 40 °C (104 °F) Non-condensing
- Operating Altitude: Up to 2000 m (6562 ft)
- Weight: 46 lbs.
- Dimensions (DxWxH): 17 x 13.5 x 5.5 in.
- Line Voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability
- Line Frequency: 50 or 60 Hz, ± 5 %
- Power Consumption: 260 VA / 210 W / 717 BTU Maximum
G1316C – TCC
- Temperature Stability: ± 0.05 °C
- Temperature Accuracy: ± 0.8 °C ± 0.5 °C
- Column Capacity Three 30 cm
- Ambient Operating Temperature: 0–55 °C (32–131 °F)
- Ambient Non-Operating Temperature: -40 – 70 °C (-40 – 158 °F)
- Humidity: < 95 % r.h. at 40 °C (104 °F) Non-condensing
- Operating Altitude: Up to 2000 m (6562 ft)
- Line Voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability
- Line Frequency: 50 or 60 Hz, ± 5 %
- Power Consumption: 320 VA / 150W / 512 BTU Maximum
- Weight: 22 lbs.
- Dimensions (DxWxH): 17 x 13.5 x 5.5 in.
G4212A – D.A.D
-
- Ambient Operating Temperature: 4–40 °C (39–104 °F)
- Humidity: < 80 % r.h. at 40 °C (104 °F) Non-condensing
- Operating Altitude: Up to 2000 m (6562 ft)
- Detection Type: 1024-element photodiode array
- Light Source: Deuterium lamp Equipped with RFID tag that holds lamp typical information.
- Wavelength Range: 190 – 640 nm
- Drift: < 0.5 × 10-3 AU/hr at 230 nm
- Linear Absorbance Range: > 2.0 AU (5 %) at 265 nm
- Wavelength Accuracy: ± 1 nm
- Line Voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability
- Line Frequency: 50 or 60 Hz, ± 5 %
- Power Consumption: 160 VA / 130 W / 444 BTU Maximum
- Weight: 26 lbs.