Description
Agilent 1200 Series HPLC System w/Computer and Software
This Agilent 1200 Series System is in very good condition. Retrieved from working lab; we’ve tested components. Will come with computer and ChemStation software.
G1337A – Micro Well-Plate Autosampler (µWPS)
- Injection Range: 0.01–8 µL (small loop) or 0.01–40 µL (extended loop) in 0.01 µL increments.
- Pressure Range: Up to 400 bar (5880 psi).
- Precision: Typically, <0.5% RSD (5–40 µL); <1% RSD (1–5 µL); <3% RSD (0.2–1 µL).
- Sample Capacity: 2× well-plates (MTP) + 10 × 2 mL vials (using standard tray).
- Carry-over: Typically, <0.05%.
- Injection Cycle Time: Typically, <30 seconds.
- Sample Viscosity Range: 0.2–5 cP.
- Dimensions (DxWxH): 17 x 13.5 x 8 in.
- Weight: 34.2 lbs.
G1330B – Autosampler Thermostat
- Temperature Range: 4°C to 40°C
- Technology: Peltier-controlled heat exchanger for cooling and heating
- Dimensions (H x W x D): Approximately 5.5 x 13.5 x 17 inches
- Weight: Approximately 46 lbs
- Voltage: 100-120 or 220-240 VAC
- Line Frequency: 50 or 60 Hz
- Power Consumption: Approximately 260 VA for the thermostat
G1316A – TCC
- Weight: 25 lbs.
- Dimensions (HxWxD): 5.5 × 13.5 × 17 in.
- Line Voltage: 100 – 240 VAC, ± 10%
- Line Frequency: 50 or 60 Hz, ± 5%
- Power Consumption: 220 VA, 85 W / 290 BTU
- Ambient Operating Temp: 0–55°C (32–131°F)
- Ambient Non-Operating Temp: -40–70°C (-4–158°F)
- Humidity: < 95%, at 25–40 °C (77–104 °F) non-condensing
- Operating Altitude: Up to 2000 m (6500 ft)
- Non-Operating Altitude: Up to 4600 m (14950 ft) For storing the instrument
- Safety Standards: IEC, CSA, UL, EN
- Installation Category II, Pollution Degree 2
G1315B – Diode Array Detector (DAD)
- Detector Type: 1024 element photodiode array.
- Wavelength Range: 190 – 950 nm.
- Light Source: Deuterium (UV) and Tungsten (VIS) lamps.
- Short Term Noise (ASTM): ± 1 × 10-5 AU at 254 and 750 nm
- Drift: 2 × 10-3 AU/hr. at 254 nm
- Linear Absorbance Range: > 2 AU (upper limit)
- Wavelength Accuracy: ± 1 nm
- Slit Width: Programmable 1, 2, 4, 8, 16 nm.
- Data Rate: Up to 80 Hz.
- Flow Cell (Standard): 13 \(\mu\text{l}\) volume, 10 mm cell path length, 120 bar pressure maximum.
G1379B – 4-channel Micro Vacuum Degasser
- Maximum Flow Rate: 0 – 5 ml/min per channel.
- Number of Channels: 4.
- Internal Volume per Channel: Approximately 1 ml.
- Materials in Contact with Solvent: PTFE, FEP, and PEEK.
- pH Range: 1 – 14.
- Dimensions (WxDxH): 13.5 x 17 x 3.1 in.
- Weight: 16 lbs.
- Electrical Requirements: 100 – 240 VAC, ±10%, 50/60 Hz, ±5%.
- Power Consumption: 30 VA / 30 W / 102 BTU Maximum.
- Ambient Operating Temperature: 0 – 55 °C (32 – 131 °F).
- Operating Altitude: Up to 2000 m (6562 ft).
- Humidity: < 95% non-condensing.
G1376A – Capillary Pump
-
- Flow Range: 0.01 – 20 µL/min (standard), 0.01 – 100 µL/min (with extended flow range kit).
- Pressure Range: Up to 400 bar (5880 psi).
- Flow Accuracy: < 0.7% RSD or 0.03% SD (at 10-50 µl/min
- Delay Volume: Low delay volume for fast gradients.
- pH Range: 1.0 – 8.5
- Dimensions (DxWxH): 17.2 x 13.5 x 7.1 in.
- Weight: 38 lbs.