Agilent ACEA NovoCyte 3000 Flow Cytometer w/ NovoSampler Pro & Fluidics Station

$21,000.00

1 in stock

SKU: 009586 Category:

Description

Agilent ACEA NovoCyte 3000 Flow Cytometer w/ NovoSampler Pro & Fluidics Station

Included in This Purchase: 
  • Acea NovoCyte 3000 
  • Agilent NovaSampler Pro 
  • Fluidics Cart and Harness 
  • NovoRinse, NovoClean, NovoFlow, and Waste caps and bottles. 
  • Desktop PC (monitor/keyboard/mouse) running NovoExpress V1.6.2 
  • Communication and power cables
Instrument Application: 
  • Immunophenotyping, Cell cycle analysis, Apoptosis detection, Multiplexed cytokine analysis, rare cell population detection
NovoCyte 3000 Flow Cytometer Configuration: 
  • Optics:(3) Lasers, (13) Colors, (15) Detectors: 
  • Forward Scatter Channel: 488 blue laser 
  • Side Scatter Channel: 488 blue laser 
  • 405nm Violet Laser: 780/60, 675/30, 615/20, 572/28, 530/30, 445/45. 
  • 488nm Blue Laser: 780/60, 675/30, 615/20, 572/28, 530/30. 
  • 640nm Red Laser: 780/60, 675/30. 
  • Laser Color Allocation (Laser/Channel Count): Violet/6, Blue/5 and Red/2 
  • Scatter resolution: 0.2 um 
  • Cell size: 0.2 to 50 µm 
  • Fluorescence threshold sensitivity: FITC <75 MESF, PE <50 MESF, APC <20 MESF 
  • Fluorescence resolution: <3% CV for CEN
NovoSampler Pro NS200  
  • Compatibility: Supports 24-, 48-, and 96-well plates, as well as 24 tube racks.  
  • Carryover: Low carryover of <0.1% (volume).  
  • Sample Mixing: Orbital shaking up to 3000 rpm for consistent sample mixing.  
  • Automation: Walk-away convenience for time and cost savings.  
  • Software Integration: Controlled via NovoExpress software.  
  • Applications: Suitable for various assays, including apoptosis and cell cycle analysis.
Fluidics 
    • Sample acquisition rate: 35,000 events/second 
    • Volumetric absolute count precision: CV <5% 
    • Sample flow rate: 5 to 120 μL/min 
    • Sheath flow rate: 6.5 mL/min 
    • Sample aspiration volume: 10 μL to 5 mL 
    • Fluid container capacity: 3 L sheath, 3 L waste, 500 mL cleaning, 500 mL decontamination 
    • Carryover: <0.1% 
    • Manual sample loading: 12 x 75 mm tube, 1.5 mL Eppendorf tube 
    • Automatic sample loading with NovaSampler Pro: standard 96-well plates (flat-bottom, U-bottom, V-bottom), standard 24-well and 48-well plates, and ACEA NovoSampler Pro 24-tube rack for 12 × 75 mm tubes 
    • Power requirements: input: 12 VDC, power: 90 VA 

Ebay

Contact Us

Additional information

Weight 210 lbs
Dimensions 38 × 38 × 38 in

260 Interstate Circle
Suite 2A
Frederick , MD 21704

Call us

301 803 9722
240 375 6333