Waters Acquity UPLC System w/Computer & Software
Waters Acquity PDA Detector (186015026)
- Wavelength range: 190 to 500 nm, Optical resolution: 1.2 nm
- Digital Resolution: 1.2, 2.4, 3.6, 4.8, 6.0, 7.2, 8.4, 9.6, 10.8, 12.0
- Wavelength accuracy: ±1.0 nm.
- Wavelength Repeatability: ±0.1 nm
- Digital Filter: Variable with data rate.
- Order Filter, Fixed 340 nm to 500 nm
- Environmental Stability: ±2 °C/hour.
- Analytical Flow Cell Conditions: 0.5 mL/min, 10/90 Acetonitrile/water.
- Linearity: < 5% at 2.0 AU, propylparaben series at 257 nm.
- Data Rate: 1, 2, 5, 10, 20, 40, and 80.
- Operating Temperature: 4 to 40°C (39.2 to 104°F).
- Operating Humidity: <90%, noncondensing.
- Shipping and Storage Temperature: −30 to 60°C (−22 to 140°F).
- Acoustic Noise (instrument generated): <65 dBA.
Waters Acquity Column Manager (186015007)
- The Acquity UPLC Column Manager (CM-Aux) is designed for high productivity.
- It provides automated switching for up to four columns with dimensions up to 2.1 mm in internal diameter (I.D.) and 150 mm in length, as well as a bypass channel for flow injections.
- Heating and cooling from 10 to 90 °C
- Lifetime usage information tracked for each column
- Advanced design pre-column solvent heating/ post-column passive cooling
Waters Acquity Sample Manager (186015006)
- Heater / Cooler: 4 to 40°C (39.2 to 104°F), +3 °C (+5.4 °F) in 20°C (68°F) ambient conditions. Programmable in 1°C (1.8°F) increments
- Number of ANSI compliant plates: Total of up to 2:1 standard microtiter plates, or 11 intermediate height plates, or 11 intermediate height plates, or 7 deep-well (or 2-mL vial) plates, and combination thereof.
- Maximum Sample Capacity: Total of up to 8,064 samples: in twenty one (21) 385-well plates.
- Operating Temperature: 4 to 40°C (39.2 to 104°F)
- Operating Humidity: <90% noncondensing
- Shipping and storage temperature: -30 to 60°C (-22 to 140°F) <90% noncondensing
- Acoustic Noise (instrument generated): <65 dBA
Waters Acquity Binary Solvent Manager (186015001)
- Number of Solvents: Up to four, in any combination of two, Al or A2 and Bl or B2
- Solvent Storage: Solvents Tray accommodates up to four chromatographic solvents, two Sample Manager wash solvents and one Binary Solvent Manager seal wash solvent.
- Solvent conditioning: Vacuum degassing (Six-channel): one channel per solvent, and two channels for Sample Manager wash solvents
- Operating Flow Rate Range: 010 to 2.000 mL/min, in 0.001 mL increments
- Compressibility Compensation: Automatic and continuous
- Plunger Seal Wash: Integral, active, programmable
- Maximum Operating Pressure: 15,000 psi up to 1 mL/min, 9,000 psi up to 2 mL/min per pump, not more than 15,000 psi total.
- Flow Precision: 0.075% RSO or ±0.02 min SO, six replicates, based on retention time or volumetric measures (0.500 to 2.000 ml/min).
- Flow Accuracy: ± 1.0% at 0.5 mL/min with degassed methanol, per Waters AQT/SystemsQT protocol.
- Primary wetted materials: 316 stainless steel, UHMWPE, sapphire, ruby, FEP, PTFE, ETFE, diamond-like coating, PEEK and PEEK alloys, titanium alloys
UPLC Column Heater (186015011)
- Temperature Control: Within the range of 20 °C (or ambient plus 5 °C, whichever is higher) to 90 °C, settable in 0.1 °C increments.
Temperature Distribution: ± 3 °C up to 65 °C, ± 5 °C above 65 °C - Operating Temperature: 4 to 40 °C (39.2 to 104 °F)
- Operating Humidity: <95%, noncondensing
- Acoustic Noise (instrument generated): <50 dBA
- Temperature Precision: ± 0.1 °C after a reset. Temperature accuracy: ± 1 °C
Waters Acquity Solvent Tray
Computer with HPZ230 SFF Workstation
- 22” Monitor (2572-MB1), Mouse and Keyboard
- Connection cables and power cords