Promega 9311.011/E9031 GloMax Multi+ Microplate Multimode Reader

$1,400.00

1 in stock



SKU: 010744 Category:

Description

Promega 9311.011/E9031 GloMax Multi+ Microplate Multimode Reader

Item is in good condition. Item was tested for Luminescence, Fluorescence (Intensity), Visible Absorbance, UV-Visible Absorbance. This item also has the E9031 heating and shaking features. Plates have not recently been calibrated.

Detection Modes: Luminescence, Fluorescence, Visible Absorbance and UV-Visible Absorbance  

  • Sample Format: 6-, 12-, 24-, 48-, 96- and 384-well microplates  
  • Heater Maximum: 45°C ± 0.75°C  
  • Heating Interval: 0.1–120 minutes  
  • Integrated PC Operating System: Windows® CE 6  
  • User Interface: 6.6” VGA color TFT LCD display with touch screen  
  • Data Output: PC-compatible ascii file format  
  • Linear and Orbital Shaking Pattern  
  • Shaking Intensity: Low, Medium, High and Variable, (150, 300, 500rpm, and a combination of the three, respectively)  
  • Shaking Interval: 0.1–120 minutes  
  • Dimensions: 19″x18″x14″  
  • Weight: 43 lb  
  • Power Requirements: AC Power Adapter: Input: 100–240VAC, 50/60Hz Output: 24VDC, 6.3A, 150W Max.  
  • Instrument: Input: 24VDC, 5.5A Max    

Luminescence Module Specifications  

  • Detector: Top-reading, head-on photon counting photomultiplier tube (PMT)  
  • Wavelength Range: 350–650nm  
  • Detection Limit: 3 × 10–21 moles of luciferase  
  • Linear Dynamic Range: >8 logs  
  • Crosstalk: 1 million RLU using 96-well plates White Plates: 10–5 (for the Corning Costar Cat.# 3789) 10–4 (for the Greiner Bio-One LumiTrac 200) Black Plates: <10–6    

Absorbance Module Specifications  

  • Light Source: LED  
  • Detector: Top-reading, large-area photodiode  
  • Spectral Range: 450–750nm  
  • Filters Wheel Capacity: Holds up to six filters: four installed filters and two empty filter holders for user configuration  
  • Wavelengths Included: 450, 560, 600, 750nm  
  • Photometric Measuring Range: 0–5.0 OD  
  • Linear Dynamic Range: 0–4.0 OD  
  • OD Accuracy: 0.01 OD ± 3%  
  • OD Precision: 0.01 OD ± 1%  
  • Stray Light: 0.002% at 560nm in clear bottom black-wall plates    

UV-Visible Absorbance Module Specifications  

  • Light Source: Xenon Flash Lamp  
  • Detector: Top-reading photodiode  
  • Spectral Range: 200–1,100nm  
  • Filters Wheel Capacity: Holds up to six filters: four installed filters and two customizable filter paddles with 260nm and 280nm preinstalled  
  • Wavelengths Included: 260, 280, 450, 560, 600, 750nm  
  • Photometric Measuring Range: 0–5.0 OD  
  • Linear Dynamic Range: 0–3.0 OD, OD Accuracy: 0.05 OD ± 3%, OD Precision: 0.002 OD ± 3%, Stray Light: 0.001% at 560nm in clear-bottom, black-walled plates    

Fluorescence Module Specifications  

  • Light Source: Wavelength matched LED  
  • Detector: PiN-photodiode  
  • Read Position: top reading  
  • Wavelength Selection: snap-in optical kits  
  • Wavelengths Included: UV (Ex: 365nm, Em: 410–460nm) Blue (Ex: 490nm, Em: 510–570nm), Green (Ex: 525nm, Em: 580–640nm), Red (Ex: 625nm, Em: 660–720nm)  
  • Detection Limit: 0.5fmol/200µl or 1ppt of fluorescein in 96-well microplate  
  • Linear Dynamic Range: 6 logs (assay-dependent) 