G4220A – Binary Pump 

  • Ambient Operating Temp: 4–55 °C (39–131 °F)  
  • Humidity < 95 % r.h. at 40 °C (104 °F) Non-condensing  
  • Operating Altitude: Up to 2000 m (6562 ft)  
  • Flow Precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—2.0 ml/min). 
  • Pressure Operating Range: Operating pressure range 120 MPa (1200 bar), up to 2 ml/min. 
  • Line Voltage: 100 – 240 V~, ± 10 % Wide-ranging capability  
  • Line Frequency: 50 or 60 Hz, ± 5 %  
  • Power Consumption: 350 VA / 270 W / 922 BTU Maximum 
  • Weight: 48 lbs. 
  • Dimensions (DxWxH) 17 x 13.5 x 9.3 in.

G4226A – Autosampler 

  • Ambient Operating Temperature: 4–55 °C (39–131 °F)  
  • Humidity < 95 % r.h. at 40 °C (104 °F) Non-condensing  
  • Operating altitude Up to 2000 m (6562 ft)  
  • Sample Capacity: Flexible, including two well plates and 10 x 2 mL vials, or 30 x 6 mL vials 
  • Sample Viscosity Range 0.2 – 5 cp 
  • Line Voltage 100 – 240 V~, ± 10 % Wide-ranging capability  
  • Line Frequency 50 or 60 Hz, ± 5 %  
  • Power Consumption 200 VA / 200 W / 683 BTU Maximum 
  • Weight: 34.2 lbs.  
  • Dimensions (DxWxH): 17 x 13.5 x 8 in.

G1330B – Thermostat 

  • Ambient Operating Temperature: 4 – 40 °C (39 – 104 °F)  
  • Humidity: < 95 % r.h. at 40 °C (104 °F) Non-condensing  
  • Operating Altitude: Up to 2000 m (6562 ft)  
  • Weight: 46 lbs. 
  • Dimensions (DxWxH): 17 x 13.5 x 5.5 in.   
  • Line Voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability  
  • Line Frequency: 50 or 60 Hz, ± 5 %  
  • Power Consumption: 260 VA / 210 W / 717 BTU Maximum

G1316C – TCC 

  • Temperature Stability: ± 0.05 °C  
  • Temperature Accuracy: ± 0.8 °C ± 0.5 °C  
  • Column Capacity Three 30 cm 
  • Ambient Operating Temperature: 0–55 °C (32–131 °F)  
  • Ambient Non-Operating Temperature: -40 – 70 °C (-40 – 158 °F)  
  • Humidity: < 95 % r.h. at 40 °C (104 °F) Non-condensing  
  • Operating Altitude: Up to 2000 m (6562 ft) 
  • Line Voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability  
  • Line Frequency: 50 or 60 Hz, ± 5 %  
  • Power Consumption: 320 VA / 150W / 512 BTU Maximum 
  • Weight: 22 lbs. 
  • Dimensions (DxWxH): 17 x 13.5 x 5.5 in.

G4212A – D.A.D 

    • Ambient Operating Temperature: 4–40 °C (39–104 °F)   
    • Humidity: < 80 % r.h. at 40 °C (104 °F) Non-condensing  
    • Operating Altitude: Up to 2000 m (6562 ft) 
    • Detection Type: 1024-element photodiode array  
    • Light Source: Deuterium lamp Equipped with RFID tag that holds lamp typical information.  
    • Wavelength Range: 190 – 640 nm 
    • Drift: < 0.5 × 10-3 AU/hr at 230 nm   
    • Linear Absorbance Range: > 2.0 AU (5 %) at 265 nm   
    • Wavelength Accuracy: ± 1 nm 
    • Line Voltage: 100 – 240 VAC, ± 10 % Wide-ranging capability  
    • Line Frequency: 50 or 60 Hz, ± 5 %  
    • Power Consumption: 160 VA / 130 W / 444 BTU Maximum 
    • Weight: 26 lbs.  
    • Dimensions (DxWxH): 17 x 13.5 x 5.5 in.  