Description
Perkin Elmer Clarus 680 Gas Chromatography & Clarus SQ 8 C Mass Spec System
This system is in very good condition. Retrieved from working lab. Will come with all shown, including the Edwards pump, computer and software.
Perkin Elmer Clarus 680 Gas Chromatography
- Oven cool-down from 450°C to 50°C in less than 2 minutes.
- Unique high-performance conventional oven and injectors speed cycle times and provide best-in-class near-ambient performance.
- Integrated 108 vial liquid autosampler adds flexibility and automation.
- Temperature programmable inlets deliver performance and flexibility for more demanding applications.
- Programmable pneumatic control (PPC) adds automation.
- PerkinElmer’s complete offering allows easy integration of best-in-class headspace, headspace trap or thermal desorption as well as MS detection.
- Swafer micro-channel technology expands analytical capabilities.
- Innovative, intuitive touch-screen interface makes operation easy.
- Scalable TotalChrom Chromatography Data Systems (CDS) make data management and reporting easier than ever.
- Oven Volume (DxWxH): 9.8 x 9 x 9 in. = 794 cu. in.
Temperature Range: 10°C above ambient to 450°C or -99°C to 450°C with sub-ambient accessory
Column overheat protect: User settable up to 450 °C
Program steps: 10 program steps and 9 program ramps
Oven Temperature Range: -99°C to 450°C
Initial time: 0 to 999 min 0.1 min
Rate: 0.1 to 45 °C/min 0.1 °C
Plateau time: 0 to 999 min 0.1 min
Final oven temperature: -99°C to 450°C; 1°C
Cool-down times: From 450°C to 50°C in less than 2 minutes
Clarus SQ 8 C Mass Spectrometer
- Ionization Modes: Electron Ionization (EI) and Chemical Ionization (CI).
- Sensitivity: 1500:1 S/N (signal-to-noise).
- Detector: Clarifi™ electron multiplier detector with unique ion deflector for reduced noise.
- Pump System: 255 L/sec turbomolecular pump.
- Mass Range: 1–1200 u.
- Scan Rate: 12,500 amu/sec.
- Source Temperature: Settable 50°C – 350°C
- Maintenance: SMARTsource (Simplified Maintenance and Removal Technology) allows cleaning without removing the analyzer.
- Vacuum: <3 minutes for air/water check.
- Operating Conditions: 10 °C – 30 °C, 20–80% non-condensing relative humidity.
- Weight & Size: 49.9 kg (110 lbs) for MS; Dimensions are 50 x 32 x 77 cm (20 x 13 x 30 inches)
Edwards RV12 Two-Stage Rotary Vane Vacuum Pump
-
- Pumping Speed (60 Hz): 8.35 CFM / 14.2
- Ultimate Pressure: 2.25 x 10-3 Torr (without gas ballast), 4.5 x 10-2 Torr (with gas ballast)
- Water Vapor Tolerance: Up to 290 g/hr. (with gas ballast)
- Motor Power: 0.60 hp
- Noise Level: 48 dB(A)
- Oil Capacity: 1 L
- Weight: 63.8 lbs (29 kg)
- Inlet Port: NW25
- Oil Type: Ultra grade 19 (standard) or PFPE (chemical-resistant version)